Why do I need to refresh the environment?
Answer
The IcpRefreshEnv() function may be invoked prior to programming to achieve maximum reliability. Note that the environment refresh or reload rate is approximately 1 MB per second.
More from Category
- Do I need the RS-232 communication?→
- Do ICP family programmers operate in fully standalone mode (without PC)?→
- How can I get PJ2 checksums without a connected programmer, for example directly from a PJ2 file?→
- How can I overwrite the number of boxes or channels defined in the icp01.cfg file for the ICP2-GANG(G3) or ICP2-COMBO(G3) programmer?→
- How can I program different HEX files on different channels of the ICP2-GANG(G3) or ICP2-COMBO(G3)?→
- How can I set the security bit on the ATSAMD20E15B? The main purpose is to lock the chip memory to prevent any further access to internal data through external programming and debugging interfaces. Once the security bit is set, how can I clear it?→
- How can I turn on Gap Eliminator?→
- How to erase a controller (UUT)? Are there any hidden buttons in the software (ICP for Windows) or is not possible?During programming I am trying to clear the entire memory. Unfortunately, the memory seems to stay after programming the processor and running it→
- I’m using an ICP2(G3) to do a single word write/read to the EEPROM of an ATTiny817 at address 0x1413 and I’m having issues→
- I’m using ICP2(G3) to program ATmega640V. I have two HEX files — one for the program memory and another for the data memory. If I want to use the command-line interface, what command should I use to program both files?→
- Is provisioning available on ICP programmers?→
- PASS or FAIL 5VDC signal stays on until the next test. Is there a way to reset the device other than a 120VAC power cycle to where neither the PASS or FAIL light is on going into the next test?→
More from Hashtag
- Can the ICP2(G3) keep the T_VDD output enabled after programming is completed? We need it to continuously supply VDD.→
- How can I overwrite the number of boxes or channels defined in the icp01.cfg file for the ICP2-GANG(G3) or ICP2-COMBO(G3) programmer?→
- PASS or FAIL 5VDC signal stays on until the next test. Is there a way to reset the device other than a 120VAC power cycle to where neither the PASS or FAIL light is on going into the next test?→
- We have two ICP2(G3) programmers installed in one PC and plan to program concurrently (in parallel), we would like to know any method to avoid queueing when programming concurrently?→