How can I migrate from ICP2(G3) to ICP2-ISO(G3) or ICP2-LAN(G3)
ICP2(G3) can be replaced by ICP2-ISO(G3) to provide galvanic isolation and additional features. Please see the document: https://softlog.com/documents/Differences%20between%20ICP2(G3)%20and%20ICP2-ISO(G3)-ICP2-LAN(G3).pdf
No communication with ICP2-GANG(G3) from ICP for Windows
(A) Validate that all programmer channels are powered – Remove power- Apply 12V and observe: – all GREEN and RED LEDs should turn on for about 1-2sec – blue POWER LED should be always ON If (A])is OK then continue to (B) below (B) Sometimes incorrect box number is assigned (2…16 instead of default Box=1) […]
Unstable communication when using multiple GANG programmers in a chain
Step 1: Verify that all channels in all programmer units have the same DLL/Command Line Support (-D) setting. It must be “Yes for all” or “No for all” — mixing is not allowed. (Other options do not affect communication.)Check this via Options → OEM → Summary of Options/Families… Step 2: Confirm that all programmer units […]