“Vdd Overload” message
Answer
VDD Overload” Error — General Explanation
Case 1: Check the Target Cable
Inspect for shorts, damaged conductors, or miswiring.
Keep the cable short and ensure proper shielding/grounding.
Case 2: Target Is Externally Powered
Set VDD source = Target to avoid conflicts between power sources.
Verify that T_VDD is connected so the ICP can sense the external voltage.
Case 3: Target Is Powered by the ICP
Ensure VddMin/VddMax are set according to your PCB requirements.
Increase Vdd-to-Vpp delay (example: from 4 ms to 50 ms) to allow VDD capacitors to charge.
Always power the ICP from its 12V supply (not USB-only) to enable up to 250mA VDD current.
Verify that ICP’s VDD is not applied to your LDO output (if present); many LDOs cannot accept output voltage with an unpowered input.
Recommended Debug Method
Debug your setup in full PC-driven mode.
If the Problem Persists, please send to support@softlog.com:- icp01.cfg file- Screenshot of the error message- Screenshot of the entire screen including the status line- Electrical schematic of your PCB (or at least all programming-related connections)- Photo of your target cable